VICTOR 6310 High-precision DC Low Resistance Tester Resistance Tester
$ 84.42
- Description
- Size Guide
Description
VICTOR 6310 High-precision DC Low Resistance Tester Resistance TesterNotice:
The standard package don't include batteries.
Because,the international air shipping forbid to ship liquid,powder and batteries,
we can not put them in the package box.
Hope you can understand buy them in your local store or supermarket.
At the same time, please forgive us that we are unable to provide the English user manual.
If you need it, please contact the customer service after purchase.
Thanks for your support!
VICTOR 6310 DC resistance tester is an instrument for testing various
types of DC resistance such as transformers, motors, switches, relays, and connectors.
Its basic test accuracy can reach up to 0.05%, and it has a high measurement speed.
This instrument uses high-precision constant current to flow through the DUT and four-terminal measurement,
which effectively eliminates lead errors; uses high-precision AD conversion,
which is suitable for users to perform high-precision measurements.
The sorting function (upper super, qualified, lower super) of this instrument allows users
to freely set the upper and lower limits of resistance and the nominal value,
which greatly improves the test efficiency of this instrument.
VICTOR 6310 Introduction:
Model Number
Test range
Test measuring range
RS-232 interface
HANDLER interface
VICTOR 6310
10uΩ-20KΩ
200mΩ、2Ω、20Ω、200Ω、2KΩ、20KΩ
Optional
Optional
﹝2-2﹞Test range
VICTOR 6310: 10uΩ-20KΩ
﹝2-3﹞Test measuring range:
Test range
20mΩ
200mΩ
2Ω
20Ω
200Ω
2kΩ
20kΩ
Accuracy
0.2%±3
0.1%±3
Test current current
100mA
100mA
10mA
1mA
100uA
100uA
Readout Resolution
10uΩ
100uΩ
100uΩ
1
mΩ
10mΩ
100mΩ
1Ω
﹝2-4﹞Display range:
Direct reading: The resistance value is displayed with 5 digits,
and only 4 digits are displayed when the first digit is greater than 2.
Percentage: Display the resistance percentage with 4 digits plus 1 sign digit, and the display range is ±9999%.
Over-range display: |_||_||_||_||_|
﹝2-5﹞Test speed:
To
Fast: about 15 times/sec
Slow speed: about 8 times/sec
﹝2-6﹞Trigger mode:
Single trigger: After the instrument's HANDLER interface board (optional) receives the start signal from the outside,
it triggers a measurement once. You can also use the trigger key on the panel to trigger the measurement,
and the measurement is performed once for each key press.
If it is a single trigger when it is turned on, the 5-digit digital tube will display -----.
Continuous trigger: The trigger signal is generated internally by the instrument,
and continuously measures the tested part, and displays the result on the 5-digit digital tube.
Three, parameter specifications
﹝3-1﹞Rated working conditions:
(1) Power supply voltage 220V±10% Frequency: 50Hz±5% 60 Hz
(2) Working conditions: temperature: 0℃~40℃, relative humidity: <80%RH
(3) Storage conditions: temperature: -10℃~70℃; relative humidity: <70%RH
(4) Power: less than 30 W.
(5). The phase line L, the neutral line N,
and the ground line E of the power supply should be the same as the power plug of the instrument,
as shown in Figure 3.1.1. At the same time, the ground wire E should be reliably grounded,
otherwise there may be leakage on the surface of the instrument!
(6). After the instrument is turned on, it needs to be preheated for 20 minutes,
and then perform measurement to ensure measurement accuracy.
(7). The power socket cannot share the same socket with high-power electrical equipment,
so as not to interfere with the operation of the instrument or damage the instrument due to electrical shock.